InfoisInfo India

baffles
Heavy Industry in Coimbatore

www.bcsind.com/autoclave/
Show phone number
Remember you found this company at Infoisinfo 967789432?

Address

Madukarai (P) ,Coimbatore – 641105 , Tamil Nadu, INDIA. P.C. 641105, Coimbatore, Coimbatore.
Show map


What you should know about baffles

Manufacturers in Coimbatore

One of the most progressive Autoclave manufacturer in India . We design industrial applications autoclave machines by using control system technology .

Social networks

Products

Acoustic Enclosure is a sound arrest device. Its maximum of sound attenuation generated has been used. BCS would be arrest the unwanted noise from the machine , noise generation area and we are given the solution for the noise .">Acoustic Enclosure is a sound arrest device. Its maximum of sound attenuation generated has been used. BCS would be arrest the unwanted noise from the machine , noise generation area and we are given the solution for the noise .

TWO TYPES OF MACHINE NOISE ARREST ARE:

  • Acoustic Enclosure
  • Acoustic Barriers

ACOUSTIC ENCLOSURE:

Baffles cooling systems is specialized design and structural for the acoustic proof. Acoustic Enclosure designed to reduce noise levels at source on new or existing machinery .It will help you to meet specific noise reduction requirements within factories or can be used to reduce noise pollution to the surrounding external area .Designing the acoustic enclosure , we considered ventilation and maintenance requirement.

ACOUSTIC BARRIER:

Acoustic Barrier is also enclosure type but barrier is single line structural . Noise has generated from the source at high decibels .Here human affected the from the noise .BCS provide acoustic barrier between source and receiver.BAFFLES COOLING SYSTEMS SPECIAL FEATURES FOR ACOUSTIC ENCLOSURE AND ACOUSTIC BARRIER
  • Design the Attenuation Noise as per directly visit and measure the Noise range
  • Acoustic Insulation thickness based on the dBA range
  • Heavy density insulation was used for absorbing noise
  • Heavy gauge Perforated sheet used
  • Structural was analyzed by using structural analyze software.
  • We offered from small machinery acoustic proof to biggest valve test bed acoustic proof.
  • HEAT EXCHANGERStandards
    • TEMA Standards(Tubular Exchanger Manufacturers Association – www.tema.org
    • API (American Petroleum Institute ) Standard 660
    Codes
    • ASME Section VIII Div 1 of ASME Boiler and Pressure Vessel Code unfired Pressure Vessels – www.asme.org
    COOLING TOWER
    • Applicable Heat and Mass Transfer Standards
    • Applicable Engineering Thermodynamics
    SILENCER
    • Applicable Noise Control Standards
    We are working with following third party inspection agency (TPIA)

Services

We have specialized doing service for TIMBER COOLING TOWER and FRP cooling tower as per your existing size .Our special key features :
  • Service will conduct only expert timber workers
  • Cleaning provisions will do perfectly
  • Timbers materials are chemical treated .
  • We have using decaling compound for cleaning .
  • Better cost compare than other competitors
  • Quality and Performance is our moto .
  • Dry cooling tower is one of the moderate cooling tower. Nowadays customer preferred in this type of cooling tower . Textiles ,Leather , footwear and clothing sectors its very used for in this type cooling tower . Its main advantage is no more water subsequently for continues processing. So need of water requirement is very low compare than other cooling towers and not comes water moisture from coil.Dry cooling tower is made up of no of wounded coil . Coil has designed based on the technical specifications like flow rate and temperature . Coil tube material is copper tube , Stainless steel ( 304 series) and brass tubes .Copper tubes has been bend at the two side of the corner . In this particular bending area make radius form, so water goes to passing continuously without interruption.All the tube connected area must welded by brazing . All the welding done by qualified welders only . Finns are wrapped on the tubes . Finns wrapped based on heat transfer area .So cooling performance will be very high .

    DRY COOLING TOWER FEATURES :

    • Coil mounted on the ISO standard channels . Coils connected with parallel and serial.
    • Fan and Motor mounted on the top of the frame. Fan has been dynamic balanced with motor rotation of RPM.
    • After manufacturing coil , BCS would be conducted hydro pressure test for found any leakage on the coil tubes.
    • Tube bending joints welded by brazed by qualified welders.In this bended area thinning calculated for min thickness at the particular area.
    • Frames and sheet metal works has been powder coated.
    • In suction of air passing side fixed grid for security for finns . At the top of the area motor side fixed bird screen grid .
    • Inlet and Outlet Nozzle are welded with coil , after welding area examined by NDE ( Penetrate test ).
    • Hydro pressure test conducted after assembled the cooling tower at 21 kg/cm² ( 300 psi ).
    • No need more water consumption.
     APPLICATION AREA:
    • TEXTILE MILLS
    • KNITTING COMPANY
    • TARN & THREAD COMPANYS
    • PRINTING COMPANY
    • FABRIC
    • HOSPITALS
    • MALLS ,THEATRES
    DATA REQUIREMENT FOR DESIGN CONSTRUCTION:
    • FLOW RATE ( LPM)
    • INLET TEMPERATURE ( °C )
    • OUTLET TEMPERATURE ( °C )
    • DBT (°C )
    DRY COOLING TOWER GALLERY- See more at: http://www.bcsind.com/dry-cooling-towers-manufacturers-india/#sthash.PEnmtlc5.dpuf

Photos and videos

Additional information

  Opening times Opening Closing
* Mondays to fridays
   Monday 9:00 AM 6:30 PM
   Tuesday 9:00 AM 6:30 PM
   Wednesday 9:00 AM 6:30 PM
   Thursday 9:00 AM 6:30 PM
   Friday 9:00 AM 6:30 PM
   Sunday Closed

* Closed for lunch

Payment methods we use:

  • Other payment methods

Reviews of baffles (0)

Do you own a business?
We help you grow it

Get more clients, visibility and branding.
Let us help you achieve your targets and improve your business.

Add your company